Getting roof ventilation right is one of the most important parts of complying with building regulations. Good ventilation improves thermal performance, reduces moist air and condensation that can damage the roof structure, and helps with energy efficiency.
Here's an introductory guide to what the eaves ventilation regulations require.
What the regulations require
In Northern Ireland, the requirements are set out in the Building Regulations (Northern Ireland) and their supporting Technical Booklets. The key code of practice is BS 5250, which covers the control of condensation in buildings. (In England and Wales, the equivalent guidance is Approved Document C.) The figures below are the commonly used guidance; always check the current regulations, or ask your local council’s Building Control team, before building or altering a roof space.
The basic principle is that no roof should be affected by condensation in a way that harms its thermal or structural performance. In practice, that means providing ventilation openings in the roof space and eaves so air can flow through.
Roofs with a pitch of 15 degrees or more
Pitched roofs need ventilation openings at eaves level on opposite sides of the roof, running the full length of the eaves, to give cross ventilation. The openings should be equivalent to a continuous 10mm gap. Eaves ventilation trays or similar components stop insulation blocking the airflow where the insulation meets the roof.
Single slope roofs
On a mono-pitch roof, you need openings at eaves level and at high level, either at the roof and wall junction or through the roof covering at the highest point. The high-level opening should be equivalent to a continuous 5mm gap.
Roofs with a pitch of less than 15 degrees
For flat roofs and low-pitched roofs, ventilation openings should again be on opposite sides of the roof for cross ventilation, running the full length of the eaves, but they should be equivalent to a continuous 25mm gap.
Roofs over 10m span, or where the ceiling follows the pitch
Where the span is more than 10m, more ventilation may be needed, totalling 0.6% of the roof area. There should be a 50mm free air space between the roof deck and the insulation. The same applies to pitched roofs where the ceiling follows the slope of the roof, which also need continuous ventilation along the ridge equivalent to a 5mm gap.
Cold roofs vs warm decks
Cold roofs
Most homes have a cold roof: the insulation is laid at ceiling joist level, so the roof space is colder than the rooms below. The ventilation rules above apply to cold roofs.
Warm decks
Where proper cross ventilation isn't possible, a warm deck roof is the alternative. The insulation sits above the roof deck, beneath the waterproof membrane, with a vapour control layer that stops moisture building up. Because of this, a warm deck doesn't need ventilating.
Final thoughts
Whatever type of roof you have, getting ventilation right protects its structure and prevents damp and condensation problems. Check the current Building Regulations (Northern Ireland) and BS 5250, and if you're not a professional, have a qualified roofer carry out the work. We're always happy to advise.